Installation of your Sonishield Duo

  1. Before installing your SoniShield Duo, please follow the steps in the SoniShield Duo Quick Start Guide to turn your meter on.        SoniShield Duo Quick Start Guide
  2. Check your Appliance for a dedicated port that you can use to feed the sensor extension cable. This port is often on the back or side of the appliance and is usually close to 1 inch in diameter. If your appliance does not have a dedicated port, you will run the included flat extension cable through the hinge of the appliance.
  3. Choose where inside your appliance you want to place your Sonicu Sensor. It is recommended to place the sensor as close to the middle center of the appliance as possible, ensuring that it is not near the appliance's compressor, which would skew readings.
  4. Run the included flat extension cable through the hinge, or port, into the appliance. Make sure that you pull enough of the cable through to reach the location that you want to place the sensor. (If your appliance does have a port, make sure to seal the port with Plumber's Putty or a similar substance after running the cable through it.)
  5. Attach the sensor to the extension cable, and secure the sensor in place with zip ties, etc.
  6. Using either the included double-sided tape or a Sonishield Mount, Secure your Sonishield Duo to your appliance.
  7. Insert the Extension cable into the appropriate input on the Sonshield Duo.
  8. Use your Sonicloud Mobile app to initiate a Green LED Reset.

    Your Device is now installed!